    A stable and time tested design of 60W DC electronic load. It works in two different modes. In the first mode it acts as a constant current sinking load with both voltage and current to be set byy the user. In the second mode it can be used as a battery capacity tester.

    • constant current mode
    • max voltage: 30V
    • discharge current: 0.2A to 9.99A (+/- 0.7% + 1 digit)
    • max dissipated power: 60W
    • voltage measurement error: 1% + 2 digits

    Simple and versatile electronic load. Automatic memory function with all parameters, is well suited for automated assembly of the power adapter aging cabinet. Power supply requirement: DC12V voltage (actual voltage 11-14V) current is not less than 0.5A of power, the power will be displayed inappropriate " Err6"


    Features : 

    • Operating modes: single mode constant current (CC)
    • Discharge current: 0.20-9.99A stepper 0.1A or0.01A
    • Discharge current maximum error: 0.7% +-0.01A
    • The maximum capacity test error: 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
    • Offline (termination) Voltage Range: 1.0-25.0V stepping 1V or 0.1V
    • Discharge voltage: 1.00-30.00V
    • The maximum voltage measurement error: 1% + - 0.02V
    • Maximum power: 60W super power automatically limits the maximum current (for example, up to 60W when it can open 9.99A 6V and 20V maximum at the only open 3.00A)

    Error Codes

    • Err1: ultra-high capacity test the battery voltage.
    • Err2: battery voltage is below the set termination voltage is not connected to the battery or the battery is reversed.
    • Err3: line resistance is too large or the battery can not afford to set the discharge current.
    • Err4: circuit failure.
    • Err6: working power is inappropriate, use a standard 12V power supply, and the supply current is not less than 0.5A.
    • otP: overheating protection.
    • Ert: temperature sensor failure or the temperature is too low.
    • ouP: ultra-high voltage electron -load mode .
    • oPP: under ultra-high power electronic load mode instantly.  

     