W1209 Temperature Controlled Relay Module Thermostat Module -50℃ to +120 ℃
SKU: R-2001
Availability: IN STOCK

₹153.40 inc. GST
Ex GST: ₹130.00
Qty:
 

QuantityPrice
10 + ₹147.50
More Quantity?RFQ

Available Options


Include Acrylic Case :



Additional Info
  • Prices shown are Including GST.
  • B2B GST Credit Available.
  • Economy shipping at flat ₹59.
  • Free shipping on value > ₹2499.
  • Whatsapp Support @+917231066325
  • Estimated Delivery time?
  • Manufacturing Services

  • W1209 Temperature Controlled Relay Module Thermostat Module -50 to 120 ℃

    This thermostat module designed around STM8S003F3P6 microcontroller is ideal for temperature controller device switching control. Can work on temperature ranges of -50 to 120 ℃. 3 buttons are given on board to set the desired temperature. Relay can switch AC voltage of up to 120VAC and 20A current.

    The W1209 digital temperature controller Module W/ Display and NTC Waterproof Temperature Sensor is an incredibly low cost yet highly functional thermostat controller. With this module, you can intelligently control power to most types of electrical device based on the temperature sensed by the included high accuracy NTC temperature sensor.

     

    Displaying the current temperature
                 The thermostat will display the current temperature in °C by default. When in any other mode making no input for approximately 5 seconds will cause the thermostat to return to this default display.

    Setting the trigger temperature
                  To set the trigger temperature press the button marked ‘SET’. The seven-segment display will flash. You can now set a trigger temperature (in °C) using the ‘+’ and ‘-‘ buttons in 0.1° increments. If we didn’t press any buttons for approximately 2 seconds the trigger temperature will be store and the display will return back to the current temperature.

    Setting the parameters
                   To set any parameter first long press the ‘SET’ button for at least 5 seconds. The seven-segment display should now display ‘P0’. This represents parameter P0. Pressing the ‘+’ or ‘-‘ buttons will cycle through the various parameters (P0 to P6). Pressing the ‘SET’ button whilst any of these parameters are displayed will allow you to change the value for that parameter using the ‘+’ and ‘-‘ buttons. When finished setting a parameter press the set button to exit that option. If no buttons are pressed for approximately 5 seconds the thermostat will exit the parameter options and will return back to the default temperature display.

    Setting the cooling or heating parameter P0
                 The parameter P0 has two settings, C and H. When setting to C (default) the relay will energize when the temperature is reached. Use this setting if connecting to an air-conditioning system. When set to H the relay will de-energize when the temperature is reached. Use this setting if controlling a heating device.

    Setting the hysteresis parameter P1
                   This sets how much change in temperature must occur before the relay will change state. For example, if set to the default 2oC and the trigger temperature has been set to 25oC, it will not de-energize until the temperature falls back below 23oC. Setting this hysteresis helps stop the thermostat from continually triggering when the temperature drifts around the trip temperature.

    Setting the upper limit of the thermostat parameter P2
              This parameter limits the maximum trigger temperature that can be set. It is useful as a safety to stop an excessively high trigger temperature from accidentally being set by the user.

              Setting the lower limit of the thermostat parameter P3
                        This parameter limits the minimum trigger temperature that can be set.

    Setting temperature offset correction parameter P4
               Should you find there is a difference between the displayed temperature and the actual temperature; (for instance, if the temperature probe is on a long run of cable) you can make minor corrections to the temperature reading with this parameter.

    Setting the trigger delay parameter P5
                To reach trigger temperature this parameter allows for delaying switching of the relay. The parameter can be set in one-minute increments up to a maximum of 10 minutes.

    Setting the high-temperature alarm parameter P6
                 Setting a value for this parameter will cause the relay to switch off when the temperature reaches this setting. The seven-segment display will also show ‘—‘ to indicate an alarm condition. The relay will not re-energize until the temperature falls below this value. The default setting is OFF.

    Settings Chart

    Long press the “SET” button to activate the menu.

    (SET THE VALUES AS MENTIONED IN BRACKET)
    Code Description Range Default Value
    P0 Heat C/H (C)
    P1 Backlash Set 0.1-15  (2)
    P2 Upper Limit 110 (110)
    P3 Lower Limit -39 (-39)
    P4 Correction -7.0 ~ (0)
    P5 Delay Start Time 0-10 mins  (0)
    P6 High-Temperature Alarm 0-110  (OFF)
    Long pressing “+/-” will reset all values to their default

    APPLICATION :

    • To measure and display temperature
    • To Turn any application ON/OFF based on temperature reading. (Both AC and DC)